Alternating Flux adds a long-distance, low-loss "super high voltage" power tier to Immersive Engineering, built for hauling power across large distances.
Immersive Engineering's HV wires top out at short distances — you end up placing relays every 32 blocks. Alternating Flux (AF) fixes that:
- Long range — AF wires reach up to 96 blocks per span (configurable)
- Low loss — far less power lost over distance than standard wires
- High throughput — 131,072 IF/t (4x modern HV)
- Transmission only — AF can't power machines directly; you step down to HV through an AF Transformer, just like a real substation
Think of it as the transmission backbone of your grid: bulk power across distance on AF lines, stepped down to HV/MV/LV to actually use.
HOW TO USE
- Craft Constantan Wire, then an AF Wire Coil.
- Place AF Wire Relays as your towers and string AF coil between them.
- Build an AF Transformer — HV on the low side, AF on the high side. Converts 1:1.
- At the far end, another AF Transformer steps it back down to HV for your machines.
REQUIRES Immersive Engineering. Minecraft 1.21.1, NeoForge.
CurseForge and Modrinth only host the latest stable release of Alternating Flux. Older versions, as well as beta and alpha builds, are no longer available on either platform. If you need an older version or want to try a beta/alpha, head over to the GitHub releases page.
This is a BETA — tested on a live server but still shaking out edge cases. Please report any bugs!
Alternating Flux was originally created by AntiBlueQuirk for Minecraft 1.12.2. The concept, design, and original artwork are theirs — this is an update of their work to 1.21.1, shared publicly with their permission. Full credit to AntiBlueQuirk for the original mod.
How to Install Alternating Flux NeoForge (Mod)
Alternating Flux NeoForge by Arctonix is verified for Forge, Neoforge across Minecraft versions 1.16.5, 1.18.2, 1.19.2, 1.20.1, 1.21.1 (latest release: 1.0.6, file size: 60 KB). Follow the steps below to install it safely from ModCraft.tv:
- Click the Download button above and select your Minecraft version (1.16.5, 1.18.2, 1.19.2, 1.20.1, 1.21.1) and platform (Forge, Neoforge).
- Make sure you have the compatible loader or environment installed for Forge, Neoforge.
- Move the downloaded Alternating Flux NeoForge file into your Minecraft
.minecraft/modsfolder and launch the game.
All Versions
+ Add Version1.21.1 and 1.20.1.
ADDED
- Strain spans. A wire anchored at a strain anchor at both ends may reach twice as far. One
never grant it. The extra length is paid for in clearance — the slack is unchanged, so a span of
twice the distance hangs about twice as deep.
- The public block tag alternatingflux:strain_anchors. This is the entire contract: put a block
itself checks span length — in the coil, on the second click — so it applies to every coil in the
game, not only Alternating Flux's. Copper, electrum and steel each double from whatever their own
tier reaches.
- An Engineer's Manual entry, under Electrical Grids.
- A coil readout while a link is held, showing the distance and the reach it is actually working to.
Alternating Flux ships no strain hardware of its own, and the tag ships empty. On a plain install
nothing is tagged, every wire reaches exactly as far as it always has, and the mod says nothing about
the rule anywhere in game. The feature exists for add-ons to build on.
This tag is public API. It will not be renamed or re-scoped.
FIXED
- The AF Wire Relay's inventory icon now matches Immersive Engineering's own connectors. Its item
the icon drew smaller than every IE relay beside it, sat lower, was half size on the ground and in
item frames, and drew mostly see-through. The block itself is unchanged — the insulator cups are
still glassy in world.
1.21.1 and 1.20.1.
ADDED
- Strain spans. A wire anchored at a strain anchor at both ends may reach twice as far. One
never grant it. The extra length is paid for in clearance — the slack is unchanged, so a span of
twice the distance hangs about twice as deep.
- The public block tag alternatingflux:strain_anchors. This is the entire contract: put a block
itself checks span length — in the coil, on the second click — so it applies to every coil in the
game, not only Alternating Flux's. Copper, electrum and steel each double from whatever their own
tier reaches.
- An Engineer's Manual entry, under Electrical Grids.
- A coil readout while a link is held, showing the distance and the reach it is actually working to.
Alternating Flux ships no strain hardware of its own, and the tag ships empty. On a plain install
nothing is tagged, every wire reaches exactly as far as it always has, and the mod says nothing about
the rule anywhere in game. The feature exists for add-ons to build on.
This tag is public API. It will not be renamed or re-scoped.
FIXED
- The AF Wire Relay's inventory icon now matches Immersive Engineering's own connectors. Its item
the icon drew smaller than every IE relay beside it, sat lower, was half size on the ground and in
item frames, and drew mostly see-through. The block itself is unchanged — the insulator cups are
still glassy in world.